Sale!

Mean Well DIN-Rail DC-DC converter 12V to 48V

Original price was: $99.96.Current price is: $83.30.

Mean Well DIN-Rail DC-DC converter 12V to 48V (adjustable up to 56VDC)
(DDR-120A-48)

  • This is the best DC-DC converter for use with a Starlink Standard Antenna DC Conversion.
  • Works with the Yaosheng Starlink POE and Cable Adapters to convert your Starlink Standard antenna to 12VDC operation as safely as can be done.
  • Low Noise, Adjustable DC voltage output to compensate for voltage drop over the length of the Starlink antenna cable.

These are the same high quality power supplies used in NarwhalDX Wi-Fi Onboard Systems

  • 12VDC Input (9-14VDC)
  • 48VDC Output (48-56VDC Adjustable)
  • 100 Watt Nominal Rating
  • DIN Mountable

In Stock | Ready to Ship

Description

Product Description

This Item is : DDR-120A-48

Features:

  • Compliance to EN50155 and EN45545-2 railway standard
  • Width only 32mm
  • 2:1 wide input range
  • -40~ +70ºC wide working temperature
  • 150% peak load capability
  • DC output adjustable
  • Cooling by free air convection
  • Can be installed on DIN rail TS-35/7.5 or 15
  • Protection:Short circuit / Overload / Over voltage / Input reverse polarity / Input under voltage protection
  • 4KVdc I/O isolation (Reinforced isolation)
  • 3 years warranty

Specifications:

  • AC input voltage range: DDR-120A-12,24,48 :9~18Vdc , DDR-120B-12,24,48: 16.8~33.6Vdc
  • AC inrush current (Typ.): 5A@ 12Vdc
  • DC adjustment range: 12V: 9~14V , 24V: 24~28V ,48V: 48~56V
  • Over voltage protection: 12V: 14.4~16.8V, 24V: 28.8~33.6V, 48V: 57.6~67.2V, Protection type : Shut down o/p voltage, re-power on to recover
  • Overload protection: Nomally works within 150% rated output power for more than 3 seconds and then constant current protection 105~135% rated output power with auto-recovery
  • Reverse polarity protection:By intemal MOSFET ,no damage , recovers automatically after fault condition removed
  • Under voltage lockout protection: 12Vin (A-type):Power ON ≥ 9V ,OFF≤ 8.5V ;24Vin (B-type):Power ON ≥ 16.8V ,OFF≤ 16.5V
  • Withstand voltage:I/P-O/P: 4KVAC, I/P-F/G: 2.5KVAC ,O/P-F/G: 2.5KVAC
  • Working temperature: -40~ +70ºC (Refer to “Derating Curve”)
  • Safety standards:IEC62368-1(LVD), EAC TP TC 004 ,AS/NZS 62368.1 approved ;Design refer to UL 508
  • EMC standards: EN55032, Class B, EN61000-3-3, EN61000-4-2-3,4,5,6,8
  • Isolation resistance:I/P-O/P ,I/P-F/G , O/P-F/G: >100M Ohms/500VDC/25ºC/70% RH
  • Dimension (WxHxD) (mm):32x 125.2x 102

Additional information

Weight 1.5 lbs
Dimensions 6 × 5.5 × 2 in